EEST_50-60 workshop edition

EEST 50-60 WORKSHOP EDITION

COMPUTERIZED TEST BENCH FOR BATTERY MAINTENANCE
WORKSHOP EDITION
ALL BATTERY TYPES
SWITCHED MODE POWER SUPPLY

EEST 50-60 WORKSHOP EDITION FEATURES

ATEQ EEST-50-60-WORKSHOP
EEST-50-60-BATTERY TESTER

 1 channel of charge/discharge 50V / 60A
  Main Power Indicators
  (Voltage and intensity in charge and discharge
  on each channel can be adapted upon request)
  Immediate or delayed test start.
 Control of voltages under 16 bits.
 Temperature Measurement with type K
  thermocouples.
 Alarm for electrolyte level.
 Shut down at predefined voltages
  Min, Max or delta V.
 Shut down as a function of time –
  Protection against temperature defect

 Set up of multiple cycles and/or sequences
 Functioning in “local” mode, electronic
  management, if computer fails.
 Possibility of controlling the EEST from
  a remote location.
 Printing and automatic filing of data at
  the end of the test.
 Data protection and results saving and backup
  in case of power shutdown.
 Test result storage and research by user
  defined criteria.
 Curves drawing per phase.

EEST 50-60 WORKSHOP EDITION SPECIFICATIONS

EEST 50-60 WORKSHOP EDITION

General Electrical characteristics

Sector input 100-240VAC monophased
Frequency 50-60Hz
Temperature of use 0-50°C (0-20°C without derating)
Storage temperature -20 to +70°C
Cooling By forced ventilation
Dimensions L440 x H180 x P440 mm
Weight 35 kg

Power supply characteristics at constant voltage (charging)

Output voltage 0-50Vdc
Regulation 50 mV for a variation of I from 10 to 90%
Stability 50 mV at full charge for 8 H
Accuracy 0,1 % of reading or ±25mV

Power supply characteristics at constant current (charging)

Output current 0-60Adc
Regulation 250mA for a variation of U from 10 to 90%
Stability 250mA at full charge for 8 H
Accuracy 0,2 % of reading or ±50mA

Characteristics of the electronic charge (discharging)

Max Power 3000W
Absorbed current 0-60 Adc
Max voltage accepted 50 Vdc
Regulation in constant current 250mA for a variation of U from 10 to 90%
Stability 250mA at full charge for 8 H
Accuracy 0,2 % of reading or ±50mA

Gauge input characteristics

Voltage Measurement

Range Accuracy
+/- 50Vdc +/- 0.05% of reading or +/- 20mVl

Current Measurement

Range Accuracy
+60Adc +/-0.2% of reading or +/- 50mA

Cell voltage Number of cells : 20

Range Accuracy
+/-10Vdc +/- 0.05mV on the Full Range

Temperature

Range Accuracy
0 to 100 °C (type K thermocouple sensor) +/- 5°C (apart from sensor)

OPTIONS

Connection systems for battery elements voltage, measurement or deep discharge

Connection systems for battery elements