EEST 50-60 RACK EDITION

EEST 50-60 RACK EDITION

AUTOMATIC TEST BENCH FOR BATTERY MAINTENANCE
ELECTRONIC MANAGEMENT SYSTEM
1 CHANNEL AUTOMATIC CYCLING BENCH
ALL BATTERY TYPES
SWITCHED MODE POWER SUPPLY

EEST 50-60 RACK EDITION FEATURES

EEST 50-60-rack edition
ATEQ EEST 50-60-rack edition

1 channel of charge/discharge 50V / 60A
  Main powers available are indicative ones
  (Voltage and intensity in charge and discharge
  on each channel can be adapted upon request)
Immediate or delayed test start.
The bench can store 7 sequences of 20 stages
Charge at I or U constant + various
Discharge at I constant + various
Stand by phase
At constant intensity→stop on voltage limit
  Min, Max and time of charge and discharge
Charge at constant voltage→Charging
  stop at I min or time or ΔI

Stop on limits – Delta V on charge at I Cst
Alarms for check level of electrolyte and end
  of test
Messages display or alarm when a stage is stopped
Stage and test display
Test time display
U battery and I display and temperature display
U Max, min display and elements average
Supplied or absorbed capacity display
Internal temperature of power module display

EEST 50-60 RACK EDITION SPECIFICATIONS

EEST 50-60 RACK EDITION

General Electrical characteristics

Sector input 100-240VAC monophased
Frequency 50-60Hz
Temperature of use 0-50°C (0-20°C without derating)
Storage temperature -20 to +70°C
Cooling By forced ventilation
Dimensions L440 x H180 x P440 mm
Weight 35 kg

Power supply characteristics at constant voltage (charging)

Output voltage 0-50Vdc
Regulation 50 mV for a variation of I from 10 to 90%
Stability 50 mV at full charge for 8 H
Accuracy 0,1 % of reading or ±25mV

Power supply characteristics at constant current (charging)

Output current 0-60Adc
Regulation 250mA for a variation of U from 10 to 90%
Stability 250mA at full charge for 8 H
Accuracy 0,2 % of reading or ±50mA

Characteristics of the electronic charge (discharging)

Max Power 3000W
Absorbed current 0-60 Adc
Max voltage accepted 50 Vdc
Regulation in constant current 250mA for a variation of U from 10 to 90%
Stability 250mA at full charge for 8 H
Accuracy 0,2 % of reading or ±50mA

Gauge input characteristics

Voltage Measurement

Range Accuracy
+/- 50Vdc +/- 0.05% of reading or +/- 20mVl

Current Measurement

Range Accuracy
+60Adc +/-0.2% of reading or +/- 50mA

Cell voltage Number of cells : 20

Range Accuracy
+/-10Vdc +/- 0.05mV on the Full Range

Temperature

Range Accuracy
0 to 100 °C (type K thermocouple sensor) +/- 5°C (apart from sensor)

OPTIONS

Connection systems for battery elements voltage, measurement or deep discharge

Connection systems for battery elements